Performing Hardware Maintenance

Switch Administration

If a system failure occurs while the core dump feature is enabled, the SmartCell ZX-250 console appears similar to the example below. The SmartCell ZX-250 then begins sending images of its memory to the core dump files on the TFTP server.

Illegal access. Bus

Error.

 

 

 

 

 

IP: e0103288

PFP: e04be080

 

 

 

 

 

r0(pfp): e04be040

r1(sp): e04be0c0

 

r2(rip): e00dd7dc

r3

: 00000000

r4

: e00f8f0c

 

r5

: e0409f10

r6

: 00000003

r7

: e00f8f0c

 

r8

: e0409f40

r9

: 00000003

r10

: 00000030

 

r11

: e00f8f0f

r12

: 00000008

r13

: 00000001

 

r14

: e00d22f0

r15

: 00000008

 

 

 

 

 

 

d2000000:

Core Dump

 

 

 

 

 

 

Common DRAM dumped to /tftpboot/bobr/core_cmn

 

 

 

CPU DRAM dumped to /tftpboot/bobr/core_cpu

 

 

 

ffffffff ffffffff ffffffff ffffffff

*

 

*

d2000010:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000020:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000030:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000040:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000050:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000060:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000070:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000080:

ffffffff

ffffffff ffffffff

ffffffff

*

................

*

d2000090:

ffff

 

 

 

 

 

 

 

SmartCell ZX Start-up Code

Cabletron Systems Inc.

Copy the information displayed on the console and send it to your Cabletron customer support representative along with the core dump files.

4.9PERFORMING HARDWARE MAINTENANCE

This section gives generic instructions about how to access all user upgradable and replaceable components in the SmartCell ZX-250 ATM switch.

4.9.1Required Tools

UNumber 1 Phillips head screw driver

USmall flat-blade screw driver

UMedium flat-blade screw driver

UCabletron-approved ESD grounding device (such as a wrist strap)

4.9.2Internal Components

Figure 4-5is a diagram of the internal components common to the SmartCell ZX-250 family of switches. The five major components of the ZX-250 are

UCPU board

UMain Switch Module

UI/O modules (at least two)

4-32 SmartCell ZX-250 User Guide

Page 78
Image 78