Switch Administration | ATMRouting |
4.2.2UNI Routes
Use the add ATMRoute command to create UNI routes. For example, connect an end station adapter (with MAC address 00:11:22:33:44:55) to port A2 of the SmartCell
s• Enter the show netprefix command to obtain the netprefix of port A2
SmartCell ZX # show netprefix
PortNumber(ALL) | : a2 |
Port# NetPrefix
============================================================================
A2 39:00:00:00:00:00:00:00:00:00:14:59:00
SmartCell ZX #
¢• Reconfigure the adapter with an ATM address made from the netprefix of port A2 and the adapter’s MAC address: 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00.
••Use the add ATMRoute command to create a static UNI route that specifies port A2 and the adapter’s new ATM address.
SmartCell ZX # add atmroute |
|
|
| ||
PortNumber(A1) | : a2 |
|
| ||
AtmAddress() | : 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00 | ||||
PrefixLength(152) | : |
|
| ||
Index(0) |
| : |
|
| |
Type(Internal) | : |
|
| ||
Scope(0) |
| : |
|
| |
MetricsTag(0) | : |
|
| ||
SmartCell ZX # |
|
|
| ||
T• | Enter the show ATMRoute command to check that the UNI route was added. |
| |||
SmartCell ZX # show atmroute |
|
|
| ||
AddressNumber(ALL) | : |
|
| ||
No. Port | Route Address |
| Type Protocol | ||
================================================================================ | |||||
1 | B4 | 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:80 | I | MGMT | |
2 | B4 | 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:81 | I | MGMT | |
3 | 39:00:00:00:00:00:00:00:00:00:14:59:00 | I | PNNI | ||
4 | A2 | 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55 | I | MGMT | |
5 | 39:00:00:00:00:00:00:00:00:00:28:e9:80 | I | PNNI | ||
6 | 39:00:00:00:00:00:00:00:00:00:28:f5:00 | I | PNNI | ||
7 | B4 | 47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 | I | MGMT | |
8 | B2 | 52:00:00:00:00:00:00:00:00:00:14:51:80 | I | MGMT |
SmartCell ZX #SmartCell ZX #
The UNI route appears in the table as route number four (No. 4).
2p›F For UNI routes to work with certain devices, ILMI may also need to be disabled on the SmartCell
SmartCell