Switch Administration

ATMRouting

4.2.2UNI Routes

Use the add ATMRoute command to create UNI routes. For example, connect an end station adapter (with MAC address 00:11:22:33:44:55) to port A2 of the SmartCell ZX-250. If the adapter does not support ILMI or its ILMI is incompatible with the SmartCell ZX-250, you must create a static UNI route between the adapter and port A2 of the SmartCell ZX-250.

s• Enter the show netprefix command to obtain the netprefix of port A2

SmartCell ZX # show netprefix

PortNumber(ALL)

: a2

Port# NetPrefix

============================================================================

A2 39:00:00:00:00:00:00:00:00:00:14:59:00

SmartCell ZX #

¢• Reconfigure the adapter with an ATM address made from the netprefix of port A2 and the adapter’s MAC address: 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00.

••Use the add ATMRoute command to create a static UNI route that specifies port A2 and the adapter’s new ATM address.

SmartCell ZX # add atmroute

 

 

 

PortNumber(A1)

: a2

 

 

AtmAddress()

: 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00

PrefixLength(152)

:

 

 

Index(0)

 

:

 

 

Type(Internal)

:

 

 

Scope(0)

 

:

 

 

MetricsTag(0)

:

 

 

SmartCell ZX #

 

 

 

T•

Enter the show ATMRoute command to check that the UNI route was added.

 

SmartCell ZX # show atmroute

 

 

 

AddressNumber(ALL)

:

 

 

No. Port

Route Address

 

Type Protocol

================================================================================

1

B4

39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:80

I

MGMT

2

B4

39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:81

I

MGMT

3

--

39:00:00:00:00:00:00:00:00:00:14:59:00

I

PNNI

4

A2

39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55

I

MGMT

5

--

39:00:00:00:00:00:00:00:00:00:28:e9:80

I

PNNI

6

--

39:00:00:00:00:00:00:00:00:00:28:f5:00

I

PNNI

7

B4

47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01

I

MGMT

8

B2

52:00:00:00:00:00:00:00:00:00:14:51:80

I

MGMT

SmartCell ZX #SmartCell ZX #

The UNI route appears in the table as route number four (No. 4).

2p›F For UNI routes to work with certain devices, ILMI may also need to be disabled on the SmartCell ZX-250. Use the set PortConfig command to disable ILMI on the SmartCell ZX-250 on a per-port basis.

SmartCell ZX-250 User Guide 4-5

Page 51
Image 51
Cabletron Systems ZX-250 manual UNI Routes