Troubleshooting

Troubleshooting Congestion

5.4.3Port Congestion

s• Enter the show portstats command a few times, noting the value for cells dropped and unknown VCs dropped. Is the difference for cells dropped equal to the difference for VCs dropped?

UIf yes, the switch is improperly set up. Check the switch configuration.

UIf no, this indicates port congestion. Continue.

¢• Enter the show cacinfo command for this port. Note the bandwidth allocated for each Quality of Service on this port.

••For each class of service, enter the set porttrafficcongestion command. Set the Max threshold to the value recommended in the “Quality of Service Queue Allocation Guidelines” section.

T• Have you performed step 3 for every class of service for this port?

UIf no, go to step 3.

UIf yes, continue.

Q• Enter the set caceqbwallocscheme command for this port. Set call admission control for this port to a more conservative policy (moderate or conservative).

–•Check VC statistics for this port using either the show pvc /d or show svc /d command, whichever is appropriate.

••If the port belongs to the high virtual channel link (VCL), read the forward stats. If the port belongs to the low VCL, read the backward stats. If the port belongs to both high and low VCLs, read both stats.

G• Is the number of cells received increasing?

UIf no, go step 6.

UIf yes, continue.

n• Convert allocated bandwidth (kb/s) to cells (48 bytes).

Bandwidth in cells = (1024 X Allocated Bandwidth) / 384 where 384 = 48 cells X 8

s¥ Is the Allocated Bandwidth less than the Cell Reception Rate?

UIf no, go to step 6.

UIf yes, this VC is misbehaving. Take appropriate action, for example, terminate the VC.

SmartCell ZX-250 User Guide 5-5