Performing Hardware Maintenance

Switch Administration

>"•mamV At this point, you have direct access to the power bus of the backplane, which carries potentially hazardous voltage. DO NOT insert hands into the power supply opening. DO NOT touch the backplane. DO NOT insert any metal (or conductive) objects into the power supply opening.

–•Replace the power supply with a new power supply module or with the sheet metal blank.

%"¤›apm If you do not replace the power supply module, you MUST install the sheet metal blank in its place. Failing to do so affects the fan’s airflow and may cause overheating and component failure. You also must replace the blank to maintain EMI integrity.

4.9.15Replacing a Fuse

Use the following instructions to replace a spent fuse.

s• Turn the power switch to off, and remove the power cord.

¢• Access the fuse assembly (part of the power plug assembly) in the back of the switch.

••With a flat-blade screw driver, gently pry out the plastic fuse assembly (see Figure 4-17).

ZX-250r

ZX-250 and ZX-250i

Figure 4-17 Pry out the fuse assembly.