Cabletron Systems ZX-250 manual SmartCell ZX # show portconfig a1

Models: ZX-250

1 132
Download 132 pages 53.51 Kb
Page 32
Image 32

Using the Console

Switch Installation and Setup

Entering parameters at the command line is optional. If a command requires parameter values, it prompts you for them. For instance, in the example below, show is the operator, portconfig is the switch-attribute, and a1 is the parameter indicating that you want to show configuration information about port A1.

SmartCell ZX # show portconfig a1

==================================================

Port: A1

--------------------------------------------------

Parameter

Configured

Current

--------------------------------------------------

Sig

Type

autoConfig

pnni10

Sig

Role

other

symmetric

Interface Type

private

private

Max

vpi bits

0

0

Max

vci bits

12

12

Max

SVC vpci

0

0

Min

SVC vci

32

32

Max

Vccs

4096

4096

--------------------------------------------------

Other parameters

 

 

--------------------------------------------------

Port Admin Status

UP

 

Ilmi

Admin Status

Enabled AddressRegistration Connectivity

Oper State

UP

 

Trans Type

STS-3c

 

Media Type

MMF (S)

 

Bandwidth

155 MB

 

SmartCell ZX #

 

 

If you don’t specify parameters with the command, the console prompts you for an input value and provides a default value displayed in parenthesis. For example, if you enter show portconfig without specifying a port (as a parameter), the following appears. Here, the default of “ all” ports is presented. You can either accept the default by pressing Enter, or you can enter a specific port number. Taking the default displays the following:

SmartCell ZX # show portconfig

 

 

 

 

PortNumber(ALL)

 

 

:

 

 

Port

Intf

Sig

Trans

Media

Speed

Oper

ID

Type

Type

Type

Type

(MB/s)

State

==============================================================================

A1

private

pnni10

STS-3c

MMF (S)

155

MB

UP

A2

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

A3

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

A4

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

B1

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

B2

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

B3

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

B4(CPU)

private

uni31

STS-3c

MMF (S)

155

MB

UP

C1

private

autoConfig

STS-3c

SMF (I)

155

MB

DOWN

C2

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

C3

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

C4

private

autoConfig

STS-3c

MMF (S)

155

MB

DOWN

D1

private

autoConfig

STS-3c

CAT5 UTP

155

MB

DOWN

D2

private

autoConfig

STS-3c

CAT5 UTP

155

MB

DOWN

D3

private

autoConfig

STS-3c

CAT5 UTP

155

MB

DOWN

D4

private

autoConfig

STS-3c

CAT5 UTP

155

MB

DOWN

SmartCell ZX #

2p›F When you accept the (all) default for show, the information displayed is often abridged.

2-14 SmartCell ZX-250 User Guide

Page 32
Image 32
Cabletron Systems ZX-250 manual SmartCell ZX # show portconfig a1