COMSPHERE 3550 Series Data Service Units
5.Select Save (F1).
The Save to screen appears.
6.Select Activ (F1).
The selected application's configuration is saved to the DSU's Active operating area, and the Command Complete message appears.
Configuration Options
The Configuration Options (Opts) subbranch allows you to save, copy, and/or change configuration options. It also is the place where the DSU's ports are configured (or reconfigured) for
Refer to Chapter 5, Configuring the Unit. Chapter 5 fully explains the Opts subbranch, and provides an example of changing configuration options.
Reconfiguring a DSU Port
Select this procedure if your unit does not have a TDM/Flex installed and enabled.
.Procedure
1.Select the Confg (Configuration branch).
2.Press the F1 key to select Opts (Configuration Options subbranch).
3.Select Activ (Active), or one of the
4.Press the key until Gen (General) appears above a function key (F1, F2, or F3).
5.Select Gen. (The first configuration option in the option set is DTE Port.)
6.Select V.35 (the default is EIA232). The DTE Port setting changes to V.35.
7.Press the key to return to the Edit/Save menu.
8.Select SAVE (F1).
9.Select Activ (F1) from the Save to screen.
Command Complete appears to confirm that the configuration is saved.
Reconfiguring a TDM/Flex Port
The Connecting the DSU to a DTE section of Chapter 2 tells you how to connect Port 2 if your DSU is equipped with a TDM/Flex.
With the TDM/Flex option, you can configure each port (Port 1 or Port 2) independently (e.g., one port can be configured for
The unit is shipped with both ports configured for
To reconfigure a TDM/Flex port:
.Procedure
1.Select the Confg (Configuration branch).
2.Press the F1 key to select Opts (Configuration Options subbranch).
3.Select Activ (Active), or one of the
4.Press the key until MUX appears above a function key.
5.Select MUX (F1).
If the TDM/Flex is disabled, go to the next step. If the TDM/Flex is enabled, go to step 9.
6.Select Setup (F1).
7.For MUX Funct, select Enab.
8.Press the key to return to the Change MUX Opts menu.
9.Select Prt1 (F3). (The first configuration option in the option set is DTE Port.)
10.Select V.35 (the default is EIA232). The DTE Port setting changes to V.35.
11.Press the key to return to the Change MUX Opts menu.
12.Press the key to display Prt2.
13.Select Prt2.
14.Select V.35.
15.Press the key twice to return to the Edit/Save screen.
December 1996 |