COMSPHERE 3550 Series Data Service Units

Table 5-6

(3 of 4)

DBM Configuration Options

Call Setup:None

Next None Pswrd Cllbk Alarm Prev

Dial Backup Call Setup (only displayed when Full Mode is enabled). Establishes the level of security for call setup attempts. This configuration option prevents an invalid call from causing the DSU to switch data to the DBM.

None

Ð

Select for outgoing calls when no security is needed. If a Model 3550 or 3551 DBM calls, the unit

 

 

automatically switches to Dial Backup mode. If a non-Model 3550 or 3551 DBM calls, the unit remains in

 

 

Standby mode for 15 seconds before switching to Dial Backup mode.

Pswrd

Ð

Select when both the originating and answering DBMs must exchange valid passwords to establish a call.

 

 

This is an intermediate security level. Both devices must be either Model 3550 or 3551 DSUs and DBMs.

Cllbk

Ð

Select when you want the highest level of security. When this security level is set, the originating and

 

 

answering DBMs exchange passwords, then disconnect. The answering DBM then calls the originating

 

 

DBM back and there is a second exchange of passwords. Both devices must be either Model 3550 or

 

 

3551 DSUs and DBMs.

Alarm

Ð

Select when the DBM is to answer incoming calls only after the DSU reports a Facility Alarm. No security

 

 

checking is performed. (This feature is provided for customers that provide data services to other

 

 

customers that may not have Model 3550 or 3551 DSUs and DBMs.)

RxPwd: password

Next Chang Prev

Receive Password (only displayed when Call Setup is set to Callbk or Pswrd, and when Full Mode is enabled). The DBM expects to receive a password from the remote DBM. This password must be the remote DBM's transmit password (TxPwd). The maximum password length is 10 characters. Refer to Chapter 4 for available password characters.

Chang Ð Select and then enter the remote DBM's transmit password as the local DBM's receive password. For passwords less than 10 characters long, enter an underscore ( _ ) to the immediate right of the last character in the password. To make the password invisible from the DCP, enter a comma ( , ) as the first character.

TxPwd: password

Next Chang Prev

Transmit Password (only displayed when Call Setup is set to Callbk or Pswrd, and when Full Mode is enabled). The DBM expects to transmit a password to the remote DBM. This password must be the remote DBM's receive password (RxPwd). The maximum password length is 10 characters. Refer to Chapter 4 for available password characters.

Chang Ð Select and then enter the remote DBM's receive password as the local DBM's transmit password. For passwords less than 10 characters long, enter an underscore ( _ ) to the immediate right of the last character in the password. To make the password invisible from the DCP, enter a comma ( , ) as the first character.

5-14

December 1996

3550-A2-GB20-20

Page 80
Image 80