Operating the DSU

 

 

Table 4-3

 

Digital Test Results

Results

 

Information Displayed

 

 

 

Time:

 

Running test timer. (The Clr

 

 

selection resets the timer to

 

 

0:00:00.)

 

 

 

Tot Error:

 

Running count of bits in error;

 

 

Max, if the maximum error

 

 

count has been reached, the

 

 

maximum being 64000. (The

 

 

Clr selection resets the counter

 

 

to 0.)

 

 

 

Err Secs:

 

Running count of errored

 

 

seconds. (The Clr selection

 

 

resets the counter to 0.)

 

 

 

Run on:port nn

 

If this test was not run on an

 

 

aggregate data path, the Digital

 

 

Test was run on port nn.

 

 

 

End-to-End Test

The End-to-End (EE) Test is used to analyze a control and a tributary DSU or DBM, and the network circuit between them in both directions independently. It transmits fixed packets (or blocks) of data between DSUs or DBMs When an End-to-End Test is run, diagnostic data may be disrupted.

To view the results of the test, select Displ (Display)

and press the key to scroll through the results shown in Table 4-4.

When the test is over, the top line displays Final instead of Active.

Bit Error Rate Test

The Bit Error Rate Test (BERT) is a session- disruptive test that transmits a 511-bit pattern. It analyzes the network circuit. It can monitor the results by putting the remote DSU or DBM into Digital Loopback and checking the returned pattern for errors, or by simultaneously executing a BERT in the local DSU.

The test continues until aborted from the DCP or NMS. This test can be run on a per-port basis if a TDM/Flex is installed. A control DSU can initiate a Bit Error Rate Test in a point-to-point or a multipoint network. A tributary DSU can only initiate this test in a point-to-point network.

If nondisruptive diagnostics are in effect (if Diag Type is set to NonD), diagnostic data can be disrupted.

To display the results of the test, press F2 to select Displ. The results are shown in Table 4-5. To clear the results of the test and clear the counters to zero, press F3 to select Clr.

 

 

 

Table 4-4

 

 

End-to-End Test Results

Results

Reported By1

 

Information Displayed

Time:

Local and

 

Running test timer. (The Clr selection resets the timer to 0:00:00.)

 

Remote DSU/DBM

 

 

 

 

 

 

Tot Block:

Local and remote

 

Number of blocks completed. (The Clr selection resets the counter to 0.)

 

DSU/DBM

 

 

 

 

 

 

Rx Blk err:

Local and remote

 

Number of incoming blocks with errors detected, indicating a fault in the

 

DSU/DBM

 

incoming transmission path. (The Clr selection resets the counter to 0.)

 

 

 

 

Tx Blk err:

Local and remote

 

Number of blocks with errors detected at the remote DSU, indicating a

 

DSU/DBM

 

fault in the outgoing transmission path. (The Clr selection resets the

 

 

 

counter to 0.)

 

 

 

 

Rx TimOuts:

Local DSU/DBM only

 

Number of blocks that were not received or acknowledged by the

 

 

 

remote DSU or DBM. (The Clr selection resets the counter to 0.)

 

 

 

 

1 Local refers to the test initiator.

 

 

3550-A2-GB20-20

December 1996

4-11

Page 56
Image 56
Paradyne 3551 manual End-to-End Test, Bit Error Rate Test