COMSPHERE 3550 Series Data Service Units

Verifying DBM Operation

If a DBM is installed, test the tributary DBM for dial tone, and verify that the DSU can place and receive calls.

.Procedure

1.Select Bckup (F2).

2.Select Dial to establish a dialed call to the tributary.

(Refer to Chapter 4 for the procedure for entering telephone numbers.)

3.Select !Dial to switch to the dial circuit.

4.Perform a Digital Test following the DBM path rather than the DSU path.

(No error message should appear.)

5.Select DrBU to drop the backup call.

6.Perform a Digital Test on the DBM. Follow the Verifying the Network procedure, selecting DBM instead of DSU (Step 2).

Verifying TDM/Flex Operation

If a TDM/Flex is installed, perform a Digital Test on each port.

Other Tests

The following lists the tests available on your DSU. Refer to the Test Branch section of Chapter 4 for further test information, as well as more detail on how to configure and operate the DSU. Refer to Appendix A to determine how best to access each test.

Device Test (Devic)

Local Loopback (LL)

DTE Loopback (DTE)

Digital Loopback (DL)

Remote Digital Loopback (RL)

Bilateral Loopback

Digital Test (DT)

End-to-End Test (EE)

Bit Error Rate Test (BERT)

Lamp Test (Lamp)

2-12

December 1996

3550-A2-GB20-20

Page 33
Image 33
Paradyne 3551 manual Verifying DBM Operation, Verifying TDM/Flex Operation, Other Tests