COMSPHERE 3550 Series Data Service Units

Table 4-5

Bit Error Rate Test Results

Results

Information Displayed

 

 

Time:

Running test timer. (The Clr

 

selection resets the timer to

 

0:00:00.)

 

 

Tot Error:

Running count of bits in

 

error; Max, if the maximum error

 

count has been reached, which

 

is 64000. (The Clr selection

 

resets the counter to 0.)

 

 

Err Secs:

Running count of errored

 

seconds. Errored second is at

 

least one error is detected during

 

a 1-second time period. (The Clr

 

selection resets the counter to

 

0.)

 

 

Run on:port nn

Port selected for testing.

 

 

Lamp Test

The Lamp Test is a test of the status indicators (LEDs) and liquid crystal display (LCD) on the DSU's control panel (both models). Any indicator that does not flash is not functional.

Note that if all LEDs are functioning, all the indicators on the Model 3550 DCP are flashing steadily. In a COMSPHERE 3000 Series Carrier, the indicators on the SDCP remain ON. The LCD on the DCP or SDCP alternately flashes solid blocks, moving from position to position on the display until the test is aborted.

Pressing any key except the key will stop the LCD portion of the Lamp Test and return you to the DSU Test menu so you can abort the test. Once aborted, the LCD and LEDs stop flashing.

Configuration Branch

The Configuration (Confg) branch allows you to configure or customize the DSU and its equipment (DBM or TDM/Flex) to fit your site's requirements, to enter and change telephone numbers (if a DBM is installed), and to specify the mode for viewing or editing configuration options.

The 3550 Series DSUs have two special features that simplify configuration of your DSU: Menu mode and the preset (factory-set) unit configurations to fit typical DSU applications.

It is recommended that you set the Menu mode before you select an application configuration, or access option sets.

Selecting Menu Mode

By selecting Menu from the Configuration Options (Opts) branch, you can

View and configure options in each option set, or

View and edit only those options that are more likely to change.

This feature saves time and simplifies customization of your DSU's configuration. Appendix B, Configuration Worksheets, summarizes the unit's configuration options for each Menu mode selection.

.Procedure

1.Select Local (F1) for the local DSU.

2.Press the key until Confg (Configuration branch) is displayed.

3.Select the function key directly below Opts (F3).

4.Press the key to display Menu.

5.Select Menu (F1). Full Mode appears on the first line of the LCD.

4-12

December 1996

3550-A2-GB20-20

Page 57
Image 57