COMSPHERE 3550 Series Data Service Units
|
| Table |
|
| DSU Status Indicators |
Label | Color | Description |
|
|
|
OK | Green | Health and status indicator: DSU operation is normal. (The DSU has not |
|
| detected any of the faults listed under Alrm, below.) |
|
| This indicator flashes two times per second if a message from the NMS is |
|
| present. |
|
|
|
Alrm | Red | Health and status indicator: |
|
| There is a fault in the local or remote DSU, DBM, or DDS facility, or there is a |
|
| corrupted configuration. |
|
| The following alarms at the local or remote DSU cause the Alrm status |
|
| indicator on the affected DSU to light: |
|
| Configuration Corrupt |
|
| Device Fault |
|
| Dial Tone Test Failure |
|
| DTR Alarm |
|
| Facility Alarm |
|
| MUX Failure |
|
| No Response |
|
| Redundant Power Alarm |
|
| Streaming Terminal |
|
| Subnetwork Alarm |
|
| |
|
| |
Test | Yellow | Active device (DSU or DBM) is either performing a test or other DSUs or DBMs |
|
| are in Test mode.1 |
Dial | Yellow | DBM is active |
|
| Rapid flashing: Call setup in progress |
|
| Slow flashing: Call established but in Standby mode |
|
| Steady ON: Backup call established and active |
|
|
|
TXD, RXD, RTS, | Green | Internal lead states at the DSU/DTE interface(circuit designations): |
CTS, DSR, DTR, |
| Control circuit active or |
LSD |
| |
| Data circuit SPACE(ing). | |
|
| |
|
|
|
Front Panel | Yellow | DSU is currently selected at the SDCP. (The SDCP addresses one DSU at a |
(Model 3551 only) |
| time.) |
|
|
|
1 The DSU or DBM is automatically put into Test mode when a remote DSU or DBM is performing a disruptive test (e.g., a Local Loopback (LL) at the control DSU. A DSU or DBM in Test mode has its DTE interface turned Off).
|
| Table |
|
| SDCP Status Indicators |
Label | Color | Description |
|
|
|
OK | Green | Health and status indicator for the selected DSU; mirrors the OK indicator on |
|
| the DSU faceplate. |
|
|
|
Alrm | Red | Health and status indicator for the selected DSU; mirrors the Alrm indicator on |
|
| the DSU faceplate. |
|
|
|
BckUp | Yellow | Mirrors the BckUp LED on the selected DSU. |
|
|
|
Test | Yellow | Mirrors the Test indicator on the selected DSU. |
|
|
|
EC | Green | Error Correction indicator is for future use by dial network modems. |
|
|
|