COMSPHERE 3550 Series Data Service Units

Table 5-1

(1 of 2)

DSU Configuration Options

Rate(Kbps): 9.6

 

 

 

 

 

 

 

Next

64L

56

38.4

19.2

9.6

4.8

2.4

Prev

DSU Rate. Sets the data rate (in kbps) of the DSU, which must be set to match the speed of the digital (DDS) circuit.

64L

Ð

Select for 64 kbps LADS operation.

 

 

 

 

 

56 to

Ð

Set to match the speed of the DDS circuit.

 

 

 

 

2.4 kbps

 

 

 

 

 

 

 

 

 

 

NOTE: Both the control and tributary DSUs must be set to the same value.

 

 

 

 

 

 

 

 

 

 

 

PrtSp(Kbps):

9.6

 

 

 

 

 

 

 

 

Next

64

56

48

19.2

9.6

4.8

2.4

1.2

Disab

Prev

Port Speed (not displayed with a TDM/Flex installed). Sets the speed of the DTE port interface. The port speed is set to any value less than or equal to the DSU Rate(Kbps) set above. The DSU performs rate adaption if the port speed is set to less than the DDS rate.

64 to

Ð Select the DTE's port speed.

 

 

1.2 kbps

 

 

 

 

 

 

Disab

Ð Disables PrtSp(Kbps).

 

 

 

 

 

 

 

TxClkSource: DDS

 

 

 

 

Next

Int

Ext

Prt1

Prt2

DDS

Prev

Transmit Clock Source. Specifies the transmit timing source for the DSU.

Int

Ð Select internal clock source to take timing from the DSU.

Ext

Ð Select external clock source when timing is taken from the external Transmit Timing lead on Port 1 only

 

 

(not displayed if a TDM/Flex is installed).

Prt1 or

Ð Select the port that timing is to be taken from, using the selected port's external Transmit

Prt2

 

Timing lead (Prt2 is only displayed if a TDM/Flex is installed and enabled).

DDS

Ð Select the DDS network when the DSU is connected to a DDS network and the network provides the

 

 

timing, or when a LADS configuration with a remote DSU is providing the timing.

 

 

 

 

 

Msg Clamp: Enab

 

 

 

 

Next

Enab

Disab

Prev

 

 

Message Clamping (only displayed when Full Mode is enabled). Controls data lead behavior when disruptive diagnostic tests and commands are received from the remote DSU. It applies to both the DSU and DBM.

Enab

Ð

Select to prevent diagnostic messages from reaching the DTE interface.

Disab

Ð

Select if the remote DSU is configured for switched RTS; that is, RTS Control is set to DTE in the General

 

 

(Gen) configuration options.

 

 

 

TxElasStor: Disab

 

 

Next

 

Enab

Disab

Prev

Transmit Elastic Store (only displayed when Full Mode is enabled and a TDM/Flex is not installed). Using a transmit buffer on the DSU's transmitted data (TXD) lead, serial data is clocked into the DSU's elastic store using clock provided by the extended circuit received clock lead. The DSU's own system timing is used to clock data out of the buffer.

Transmit Elastic Store is reset each time the unit powers-up, the buffer overflows, or after the RTS lead makes an Off-to-ON transition.

Enab

Ð

Select enable when interfacing with a DCE that receives clock from its own network source (e.g., a T1

 

 

MUX or DSU that is on the DDS network).

Disab

Ð

Select disable if you do not have an extended network or are providing the clock source to the extended

 

 

network (e.g., LADS with external clock).

5-6

December 1996

3550-A2-GB20-20

Page 72
Image 72
Paradyne 3551 manual DSU Configuration Options, Dds