COMSPHERE 3550 Series Data Service Units
Where to Place the DSU
As mentioned earlier, the DSU must be placed within 6 feet of a dedicated grounded ac outlet that is protected by a circuit breaker.
The distance between the DSU and its DTE must be within
•For the
•For the V.35 connector, the maximum distance recommended between the DSU and the DTE is nominally 1000 feet.
Allow 1 to 2 feet of clearance around the DSU for access and cable connections during installation.
Installing the DSU
Before installing the DSU, label the circuit breaker that protects the ac wall outlet, and make sure that it is set to ON. Then, proceed with the installation.
.Procedure
1.Place the DSU in its planned location. Make sure the ventilation slots are not blocked.
2.At the rear of the DSU (Figure
POWER.
3.Plug the ac transformer's
CAUTION
Only use the power transformer designed for the Model 3550 DSU. Using other transformers may result in personal injury or damage to the equipment.
Figure 2-2. Model 3550 Electrical Connection