Status Indicators and Control Panel Messages

 

 

 

Table C-3

 

 

 

(3 of 3)

 

Device Health and Status Messages

Message

 

 

Condition

 

 

MUX Device Fail

Internal failure in the TDM/Flex is detected.

 

 

MUX CommunicFail

No reply from TDM/Flex. The DSU periodically polls the TDM/Flex for health and status.

 

When the DSU does not receive a response, the message MUX CommunicFail

 

appears in the Health and Status report.

 

 

Prtnnn Disable

Transmitter at port nnn (01 or 02, or All is disabled. (Go to the Control branch to enable

 

the port.)

 

 

Portnnn DTR Alarm

The DTR lead at port nnn (01 or 02, or All) has been Off for more than 30 seconds.

 

 

Prtnnn StreamTerm

Streaming terminal. DTE at port nnn (01 or 02, or All) has its RTS lead turned ON

 

longer than the predefined time.

PnnnTst: test,init

The DSU is running a test on port nnn (01 or 02), initiated from init.

 

test is one of the following tests:

 

BERT

Ð

Bit Error Rate Test

 

DL

Ð

Digital Loopback

 

DT

Ð

Digital Test

 

DTE

Ð

DTE Loopback

 

RL

Ð

Remote Digital Loopback

 

TM

Ð

Test Mode

 

init is one of the following initiators:

 

DTE

Ð

Data T erminal Equipment

 

FP

Ð

Front Panel (the DCP)

 

NMS

Ð

Network Management System

 

Remt

Ð

Remote DSU

Redun Fan Alarm

Indicates a problem with the fan on the ±48 Vdc Central Office Power Unit.

 

 

Redun Pwr Alarm

Indicates a problem with the power on the ±48 Vdc Central Office Power Unit.

 

 

Subnetwrk Alarm

A major alarm was set Off by one of the devices in your subnetwork. Check the

 

Subnetwork Health and Status report.

 

 

Sub-normal Speed

The DSU is operating at a dial backup speed that is less than the DDS network speed.

 

 

Subtree Truncat

Downstream health and status information has been truncated because it overflowed

 

system limits.

 

 

 

OutofFrameThresh

For DSUs operating on a single port (rate adaption or nondisruptive), TDM, the local

 

DSU has detected a continuous MUX Out-of-Frame condition. The alarm clears when a

 

local DSU synchronizes with a remote DSU.

 

On a point-to-point circuit, if the alarm continues and the local DSU is configured for

 

automatic backup, the local DSU disruptively tests the DDS circuit. If the test fails, the

 

local DSU initiates a DDS Facility Alarm and initiates dial backup.

nn.n DDS

Indicates the speed (nn.n) of the active core (DSU or DBM) when there are no alarms.

 

 

 

 

3550-A2-GB20-20

December 1996

C-5

Page 109
Image 109
Paradyne 3551 manual Message Condition, Pnnn Tst test,init