COMSPHERE 3550 Series Data Service Units

 

 

Table 4-2

 

 

Backup Branch Menu Selections

Current

Backup

Effect

Backup Mode

Command

 

 

 

 

Idle

Bkup

Dial out, establish, and switch to dialed link (Dial Backup mode).

 

Dial

Dial out and establish dialed link (Standby mode). (Data is routed over the DDS

 

 

circuit.)

 

 

 

Standby

Disc

Disconnect dialed link (Idle mode).

 

Dial

Switch data to dialed link (Dial Backup mode).

 

 

 

Dial Backup

DrBU

Disconnect dialed link and switch to private line (Idle mode).

 

DDS

Switch data to DDS (Standby mode).

 

 

 

External Backup

ExtBU

If ExtBU in the ExtBU option set is set to Orig, this command is displayed (Idle

 

 

mode). Select this command to establish a backup call. When the backup call is

 

 

established, the DSU switches data to the dialed link.

 

 

 

 

DrBU

Disconnect dialed link and switch to private line (Dial Backup mode).

 

 

 

Manual Backup

You can control each step of a backup attempt by following one of these procedures.

5.Select Dial (F2); the DBM places the call.

6.Once the dialed call has been established, select !Dial to switch data to the dial path.

Placing a Backup Call

To place a backup call:

.Procedure

1.Go to the Bkup option set under the Confg branch and set Auto Bckup to Disab.

2.Select Bckup (Backup branch) to select a telephone number from the Backup Directory.

If the telephone number in the Backup Directory is the number you want to dial, go to Step 5.

3.Select Dial, the Backup Dir screen is displayed identifying the Backup Directory indicator.

4.Select another telephone number to call:

Press the F1 key ( ) to increment the directory indicator (e.g., 1 to 2).

Press the F2 key ( ) to decrement the indicator (e.g., 2 to 1).

Manual DDS Restoration

Data can be switched back to the DDS circuit once DDS service has been restored.

.Procedure

1.From the Bckup branch, select !DDS to restore data traffic to the DDS circuit.

2.If the DDS circuit operates normally after the switch, select DrBU to drop the backup circuit.

3.If the DDS circuit fails to perform reliably, select !Dial again to quickly route data back over the dialed connection.

Manual Dial Backup Termination

If in Standby mode, select Disc.

If in Dial Backup mode, select DrBU.

If in External Backup mode, select DrBU.

4-8

December 1996

3550-A2-GB20-20

Page 53
Image 53
Paradyne 3551 manual Manual Backup, Placing a Backup Call, Manual DDS Restoration, Manual Dial Backup Termination