COMSPHERE 3550 Series Data Service Units

 

 

 

 

Table 5-8

 

 

 

 

(2 of 4)

 

 

 

 

General Configuration Options

 

 

 

 

LSD Lead: Std

 

 

 

Next

Std

Delay

FrcOn

Prev

Line Signal Detect Lead (only displayed when Full Mode is enabled). Controls behavior of the LSD lead.

Std

Ð Select standard so that the LSD lead goes Off when a control mode idle (CMI) signal is received from the

 

 

DDS network, or there is a DDS failure.

Delay

Ð Select only if you do not want the DSU to respond to a network alarm condition or CMI signal. When

 

 

selected, LSD only goes Off after repeated call attempts fail, and the period of time set in Tries Time-out

 

 

(in the Backup option set) expires. Make sure that Auto Backup (in the Backup option set) is enabled.

FrcOn

Ð Select to keep LSD on as long as the DSU has power.

 

 

 

DSR FrcOn: Enab

 

 

Next

Enab

Disab

Prev

 

Data Set Ready Forced On (only displayed when Full Mode is enabled, and a TDM/Flex is not installed). Provides the ability to override any other options controlling the DSR lead.

Enab

Ð

Select for DSR to remain ON as long as the device is working, regardless of any tests or network alarms.

Disab

Ð

Select if DSR is to function as an active lead, reflecting various test and alarm conditions.

 

 

 

SystemStat: Enab

 

 

Next

Enab

Disab

Prev

System Status (only displayed when Full Mode is enabled). Controls the behavior of the DSR lead in response to a No Signal, Out-of-Service, or Out-of-Frame alarm from the network.

Enab

Ð Select if a network alarm is to turn DSR Off.

Disab

Ð Select if a Model 3551 DSU with a V.32 DBM that is configured with its Primary Core configuration option

 

 

set to Yes (DBM option set) is part of your network configuration. When selected, a network alarm will not

 

 

affect DSR.

 

 

 

DSR on Tst: Enab

 

Next

Enab

Disab

Prev

Data Set Ready On in Test (only displayed when Full Mode is enabled, and a TDM/Flex is not installed). Controls the behavior of the DSR lead during testing.

Enab

Ð

Select so that DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to

 

 

send test messages to the DSU.

Disab

Ð

Select so that DSR is Off during testing.

 

 

 

Circ Assur:Disab

 

 

Next

Enab

Disab

Prev

Circuit Assurance (only displayed when LinkConfig is set to Pt-Pt and Full Mode is enabled). Controls behavior of the CTS lead in response to a data signal from the network. If CTS Cntrl is set to =RTS or FrcOn, this configuration option is ignored.

Enab

Ð

Select to have the DSU turn Off the CTS lead if a control mode idle (CMI) signal is received.

Disab

Ð

Select if the DSU is to be unaffected by the CMI.

 

RespondRDL:Disab for MPTC; Enab for all other configurations

Next

Enab

Disab

Prev

Respond to Remote Digital Loopback (only displayed when Full Mode is enabled). Determines whether the DSU responds to a V.54 Remote Loopback request.

Enab

Ð

Select to perform a Digital Loopback.

Disab

Ð

Select to ignore the Loopback command.