Status Indicators and Control Panel Messages

Control Panel Messages

This section shows the screen format of messages appearing on the control panel and describes the various messages.

Three types of messages are included: health and status, progress, and error messages.

Format

The format of the control panel messages is shown below.

Command Name

Message

F1 F2 F3

Health and Status Messages

There are three types of health and status messages. Device Health and Status messages are described in Table C-3, Expanded Health and Status messages are described in Table C-4, and Subnetwork Health and Status messages are described in Table C-5.

Table C-3

(1 of 3)

Device Health and Status Messages

Message

 

 

Condition

 

 

CMI Fac Alarm

Facility Alarm on CMI (FacAlOnCMI) configuration option is enabled and control mode

 

idle (CMI) is being received.

 

 

Config Corrupt

Configuration is corrupt. Reset all configuration options from one of the default

 

(factory-loaded) option sets stored in the PTPC, PTPT, MPTC, or MPTT.

DBM:Device Fail

Internal failure is detected in the DBM.

 

 

DBM:Disable

DBM transmitter is disabled. DBM is in Idle mode, but no calls can be initiated or

 

answered.

 

 

nn.nDBM:mode

nn.n indicates the DBM speed; mode is one of the following:

 

Standby

Ð A dialed connection is made, but the data is still routed over the DDS

 

 

 

circuit. The first line shows the dial backup connection time.

 

Active

Ð A dialed connection is made, and data has been routed over that line.

 

 

nn.nExternBU

nn.n indicates the external DBU's speed:

 

External

Ð

Backup is in progress on an external DBU. (DDS line is

 

Bkup

 

disabled.)

 

 

DBMTst: test,init

The DBM is running a test, initiated from init.

 

test is one of the following tests:

 

BERT

Ð Bit Error Rate Test

 

BiL

Ð

Bilateral Loopback

 

Dev

Ð

Device Test

 

DL

Ð

Digital Loopback

 

DT

Ð

Digital Test

 

DTE

Ð

DTE Loopback

 

E-E

Ð

End-to-End Test

 

Lamp

Ð

Lamp Test

 

RL

Ð

Remote Digital Loopback

 

TM

Ð

Test Mode

 

init is one of the following initiators:

 

DTE

Ð

Data T erminal Equipment

 

FP

Ð Front Panel (the DCP)

 

NMS

Ð

Network Management System

 

Remt

Ð

Remote DSU

 

 

 

 

3550-A2-GB20-20

December 1996

C-3

Page 107
Image 107