Message

Causes

Corrective Actions

 

 

 

The memory

Invalid memory

Ensure that the memory

configuration is

configuration. The system

modules are installed in a

not optimal. The

will run but with reduced

valid configuration. See

recommended

functionality.

"General Memory Module

memory

 

Installation Guidelines" on

configuration

 

page 92. If the problem

is: <message>

 

persists, see

 

 

"Troubleshooting System

 

 

Memory" on page 181.

Write fault

Write fault on selected drive.

Faulty USB device, USB medium, optical drive assembly, hard drive, or hard- drive subsystem.

Replace the USB medium or device. Ensure that the USB, SAS backplane, or SATA cables are properly connected. See "Troubleshooting a USB Device" on page 174, "Troubleshooting an Internal USB Key" on page 183, and "Troubleshooting a Hard Drive" on page 186.

Warning: QPI links operating in Slow Speed Mode.

Warning: QPI link between <Agent X> Port <Y> and <Agent X1> <Port Y1> failed.

Warning: QPI link between <Agent X> Port <Y> and <Agent X1> <Port Y1> degraded to half-width.

The processor has bent pins.

The processor is not properly seated on the processor socket.

Verify that there are no bent pins on the processor. If the processor has bent pins, see "Getting Help" on page 203.

Reseat the processors. See "Removing a Processor" on page 148 and "Installing a Processor" on page 152.

If the problem persists, see "Getting Help" on page 203.

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals.