Code

Text

Causes

Corrective Actions

 

 

 

 

E1211

RAID

RAID battery is either

Reseat the RAID battery

 

Controller

missing, bad, or unable to

connector. See "Installing

 

battery

recharge due to thermal

the RAID Battery" on

 

failure.

issues.

page 147 and

 

Check

 

"Troubleshooting System

 

battery.

 

Cooling Problems" on

 

 

 

page 180.

 

 

 

E1216

3.3V

3.3V voltage regulator failed. Remove and reseat the

 

Regulator

 

PCIe expansion cards. If

 

failure.

 

the problem persists, see

 

Reseat PCIe

 

"Troubleshooting

 

cards.

 

Expansion Cards" on

 

 

 

page 189.

 

 

 

 

E1219

Disk

Storage backplane voltage

Remove and reseat the

 

Backplane

regulator has failed.

backplane. If the problem

 

power

 

persists, see "Getting

 

failure.

 

Help" on page 203.

 

Check BP

 

 

 

power cable.

 

 

 

 

 

 

E1222

CPU # VCACHE

Processor voltage regulator

Reseat the processor(s).

 

Regulator

failed.

See "Troubleshooting the

 

failure.

 

Processors" on page 190.

 

Contact

 

If the problem persists,

 

support.

 

 

 

see "Getting Help" on

 

 

 

 

 

 

page 203.

 

 

 

 

E122C

CPU Power

A power fault was detected

Remove AC power to the

 

Fault. Power

when powering up the

system for 10 seconds and

 

cycle AC.

processor(s).

restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 203.

 

 

 

 

E122E

On-board

One of the on-board voltage

Remove AC power to the

 

regulator

regulators failed.

system for 10 seconds and

 

failed. Call

 

restart the system.

 

support.

 

If the problem persists,

 

 

 

see "Getting Help" on page 203.

26

About Your System

Page 26
Image 26
Dell E06S001 E1211, Controller, E1216, Reseat PCIe, Cards, E1219 Disk, Backplane, Check BP Power cable E1222