Code | Text | Causes | Corrective Actions |
|
|
|
|
E2112 | Memory spared | The system BIOS spared the | Remove AC power to the |
| on Card x | memory because it has | system for 10 seconds and |
| DIMM ##. | determined the memory has | restart the system. |
| Power cycle | too many errors. | If the problem persists, |
| AC. |
| |
|
| see "Troubleshooting | |
|
|
| |
|
|
| System Memory" on |
|
|
| page 181. |
|
|
|
|
E2113 | Mem mirror | The system BIOS disabled | Remove AC power to the |
| OFF on DIMM | memory mirroring because | system for 10 seconds and |
| ## & ##. | it has determined one half | restart the system. |
| Power cycle | of the mirror has had too | If the problem persists, |
| AC. | many errors. "## & ##" | |
| see "Troubleshooting | ||
|
| represents the memory | |
|
| System Memory" on | |
|
| module pair implicated by | |
|
| page 181. | |
|
| the BIOS. | |
|
|
| |
|
|
|
|
I1910 | Intrusion | System cover has been | Information only. |
| detected. | removed. |
|
| Check chassis |
|
|
| cover. |
|
|
I1911 LCD Log Full. LCD overflow message. A Check SEL to maximum of ten error review all messages can display
Errors. sequentially on the LCD. The eleventh message instructs the user to check the SEL for details on the events.
Check the SEL for details on the events.
Remove AC power to the system for 10 seconds or clear the SEL.
I1912 | SEL full. | The SEL is full of events | Check the SEL for more |
| Review & | and is unable to log any | information and then |
| clear log. | more. | clear the SEL. |
|
|
|
|
W1100 | CPU VCORE | The regulator temperature | See "Troubleshooting |
| Regulator | has reached a point outside | System Cooling |
| temp | of the allowed range. | Problems" on page 180. If |
| exceeding |
| the problem persists, see |
| range. Check |
| "Getting Help" on |
| fans. |
| page 203. |
About Your System
39