Dell E06S Series Unable to launch, System Services, Image. System, Unexpected, Protected mode

Models: E06S Series E06S001

1 210
Download 210 pages 63.03 Kb
Page 57
Image 57

Message

Causes

Corrective Actions

 

 

 

Unable to launch

System halted after F10

Restart the system and

System Services

keystroke because System

update the Lifecycle

image. System

Services image is either

Controller repository to the

halted!

corrupted in the system

latest software to restore full

 

firmware or has been lost due

functionality. See the

 

to system board replacement. Lifecycle Controller user

 

 

documentation for more

 

 

information.

 

The iDRAC6 Enterprise card

Restore the flash memory

 

flash memory may be

using the latest version on

 

corrupted.

support.dell.com. See the

 

 

iDRAC6 user's guide for

 

 

instructions on performing a

 

 

field replacement of the flash

 

 

memory.

 

 

 

Unexpected

Improperly seated memory

Reseat the memory modules.

interrupt in

modules or faulty

See "Troubleshooting System

protected mode.

keyboard/mouse controller

Memory" on page 181. If the

 

chip.

problem persists, see

 

 

"Getting Help" on page 203.

 

 

 

Unsupported CPU

Processor(s) is not supported

Install a supported processor

combination.

by the system.

or processor combination.

Unsupported CPU

 

See "Processors" on page 148.

 

 

stepping detected.

Warning: A fatal A fatal system error occurred error has caused and caused the system to

system reset! reboot. Please check the system event log!

Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 173 for any faulty components specified in the SEL.