Message

Causes

Corrective Actions

 

 

 

PCIe Training

Faulty or improperly installed

Reseat the PCIe card in the

Error: Expected

PCIe card in the specified

specified slot number. See

Link Width is x,

slot.

"Troubleshooting Expansion

Actual Link Width

 

Cards" on page 189. If the

is y.

 

problem persists, see

 

 

"Getting Help" on page 203.

 

 

 

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration

initializing PCIe device;

jumper in the clear position

Error.

faulty system board.

(pins 1 and 3) and reboot the

 

 

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists, see

 

 

"Troubleshooting Expansion

 

 

Cards" on page 189.

Read fault

Requested sector not found.

The operating system cannot read from the hard drive, optical drive, or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.

Replace the optical medium, USB medium or device. Ensure that the SAS backplane, USB, or SATA cables are properly connected. See "Troubleshooting a USB Device" on page 174, "Troubleshooting an Optical Drive" on page 185, or "Troubleshooting a Hard Drive" on page 186 for the appropriate drive(s) installed in your system.

SATA Portx device

There is no device connected Information only.

not found.

to the specified SATA port.