Code

Text

Causes

Corrective Actions

 

 

 

 

E1618

Predictive

A power supply fan failure,

See "Troubleshooting

 

failure on

an over-temperature

Power Supplies" on

 

Power Supply

condition, or power supply

page 179.

 

# (### W).

communication error has

 

 

Check PSU.

caused the predictive

 

 

 

warning of an impending

 

 

 

power supply failure.

 

E161C Power Supply Specified power supply is

#(### W) attached to the system, but

lost AC

it has lost its AC input.

power. Check

 

PSU cables.

 

Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 179.

E1620 Power Supply Specified power supply's AC

#(### W) AC input is outside of the power error. allowable range.

Check PSU cables.

Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 179.

E1624

Lost power

The power supply subsystem

See "Troubleshooting

 

supply

is no longer redundant. If

Power Supplies" on

 

redundancy.

the remaining power supply

page 179.

 

Check PSU

fails, the system will shut

 

 

cables.

down.

 

 

 

 

 

E1626

Power Supply

The power supplies in the

Ensure that power

 

Mismatch.

system are not the same

supplies with matching

 

PSU1 = ### W,

wattage.

wattage are installed. See

 

PSU2 = ### W.

 

the Technical

 

 

 

Specifications outlined in

 

 

 

your system’s Getting

 

 

 

Started Guide.

E1629 Power

The system configuration

required >

requires more power than

PSU wattage.

the power supplies can

Check PSU and

provide, even with

config.

throttling.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.

30

About Your System

Page 30
Image 30
Dell E06S001 E1618 Predictive, Failure on, Lost AC, Power. Check PSU cables, E1624 Lost power, Cables, Mismatch