Code

Text

Causes

Corrective Actions

 

 

 

 

E1A15

SAS cable B

SAS cable B is missing or

Reseat the cable. If the

 

failure.

bad.

problem persists, replace

 

Check

 

cable.

 

connection.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help" on

 

 

 

page 203

E1A1D Control panel USB cable to the control USB cable not panel is missing or bad. detected.

Check cable.

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 203.

E2010 Memory not

No memory was detected in

detected.

the system.

Inspect

 

DIMMs.

 

Install memory or reseat the memory risers and memory modules. See "Installing a Memory Riser" on page 101, "Installing Memory Modules" on page 102 or "Troubleshooting System Memory" on page 181.

E2011

Memory

Memory detected, but is not

See "Troubleshooting

 

configuratio

configurable. Error detected

System Memory" on

 

n failure.

during memory

page 181.

 

Check DIMMs.

configuration.

 

 

 

 

 

E2012

Memory

Memory configured, but is

See "Troubleshooting

 

configured

unusable.

System Memory" on

 

but unusable.

 

page 181.

 

Check DIMMs.

 

 

 

 

 

 

E2013

BIOS unable

The system BIOS failed to

See "Troubleshooting

 

to shadow

copy its flash image into

System Memory" on

 

memory. Check

memory.

page 181.

 

DIMMs.

 

 

About Your System

35

Page 35
Image 35