11Run the appropriate online diagnostic test. If the problem still persists, see step 12.

12Open the system. See "Opening the System" on page 89.

13Remove the memory risers. See "Removing a Memory Riser" on page 100.

14Remove the cooling fan assembly. See "Removing the Cooling Fan Assembly" on page 118.

15If your system has four processors, remove all processors except for processor 1 and processor 2. See "Installing a Processor" on page 152.

16Install the cooling fan assembly. See "Installing the Cooling Fan Assembly" on page 120.

17Install the memory risers. See "Installing a Memory Riser" on page 101.

18Close the system. See "Closing the System" on page 90.

19Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

20Run the appropriate online diagnostic test.

If the test fails, the processor is faulty. See "Getting Help" on page 203.

If the test passes, replace processor 1 and 2 with processor 3 and processor 4. Run the appropriate online diagnostic test. If the test fails, the processor is faulty. See "Getting Help" on page 203.