Removing LCD Status Messages
For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically removed when that sensor returns to a normal state. For other faults, you must take action to remove the message from the display:
•Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.
•Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately 10 seconds, reconnect the power cable, and restart the system.
NOTE: The following LCD status messages are displayed in the simple format. See "Setup Menu" on page 16 to select the format in which the messages are displayed.
Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E1000 | Failsafe | Check the SEL for critical | Remove AC power to the |
| voltage | failure events. | system for 10 seconds and |
| error. |
| restart the system. |
| Contact |
| If the problem persists, |
| support. |
| |
|
| see "Getting Help" on | |
|
|
| |
|
|
| page 203. |
|
|
|
|
E1114 | Ambient Temp | Ambient temperature has | See "Troubleshooting |
| exceeds | reached a point outside of | System Cooling |
| allowed | the allowed range. | Problems" on page 180. |
| range. |
|
|
E1116 Memory | Memory has exceeded |
disabled, | allowable temperature and |
temp above | has been disabled to prevent |
range. Power | damage to the components. |
cycle AC. |
|
Remove AC power to the system for 10 seconds and restart the system.
See "Troubleshooting System Cooling Problems" on page 180. If the problem persists, see "Getting Help" on
page 203.