52 About Your System
Memory
Initialization
Warning: Memory
size may be
reduced.
Invalid memory
configuration. The system
will run but with less memory
than is physically available.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page92.
Memory odd/even
logic failure at
address,
read
value
expecting
value.
Faulty or improperly installed
memory modules.
See "Troubleshooting System
Memory" on page181.
Memory
write/read
failure at
address
, read
value
expecting
value.
Faulty or improperly installed
memory modules.
See "Troubleshooting System
Memory" on page181.
Memory set to
minimum
frequency.
The memory frequency may
be intentionally set lower for
power conservation.
If not an intentional setting,
check any other system
messages for possible causes.
The current memory
configuration may support
only the minimum frequency.
Ensure that your memory
configuration supports the
higher frequency. See
"General Memory Module
Installation Guidelines" on
page92.
Memory tests
terminated by
keystroke.
POST memory test was
terminated by pressing a key.
Information only.
Message Causes Corrective Actions