Code

Text

Causes

Corrective Actions

 

 

 

 

E1313

Fan

The system is no longer fan

Check LCD for additional

 

redundancy

redundant. Another fan

scrolling messages. See

 

lost. Check

failure would put the system

"Troubleshooting a Fan"

 

fans.

at risk of over-heating.

on page 180.

 

 

 

 

E1314

Critical

All fans have been removed

Ensure that the fans are

 

system

from system.

properly installed. See

 

cooling loss.

 

"Troubleshooting a Fan"

 

Check fans.

 

on page 180.

 

 

 

 

E1410

System Fatal

A fatal system error has been

Check LCD for additional

 

Error

detected.

scrolling messages.

 

detected.

 

Remove AC power to the

 

 

 

system for 10 seconds and

 

 

 

restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 203.

 

 

 

 

E1414

CPU # temp

Specified processor is out of

Ensure that the processor

 

exceeding

acceptable temperature

heat sinks are properly

 

range. Check

range.

installed. See

 

CPU heatsink.

 

"Troubleshooting the

 

 

 

Processors" on page 190

 

 

 

and "Troubleshooting

 

 

 

System Cooling

 

 

 

Problems" on page 180.

 

 

 

 

E1418

CPU # not

Specified processor is

Ensure that the specified

 

detected.

missing or bad, and the

processor is properly

 

Check CPU is

system is in an unsupported

installed. See

 

seated

configuration.

"Troubleshooting the

 

properly.

 

Processors" on page 190.

 

 

 

 

E141C

Unsupported

Processors are in an

Ensure that your

 

CPU configur- unsupported configuration.

processors match and

 

ation. Check

 

conform to the type

 

CPU or BIOS

 

described in the processor

 

revision.

 

technical specifications

 

 

 

outlined in your system’s

 

 

 

Getting Started Guide.

28

About Your System

Page 28
Image 28
Dell E06S001 E1313 Fan, Redundancy, Lost. Check, E1314 Critical, Cooling loss, Check fans E1410 System Fatal, Detected