Code

Text

Causes

Corrective Actions

 

 

 

 

W1630

Power supply

The power supply subsystem

Reseat the power supplies.

 

redundancy

is no longer fully redundant,

See "Troubleshooting

 

degraded.

but at least one more supply

Power Supplies" on

 

Check PSU

can fail before the system is

page 179.

 

cables.

at risk of shutting down.

If the problem persists,

 

 

 

 

 

 

see "Getting Help" on

 

 

 

page 203.

NOTE: For the full name of an abbreviation or acronym used in this table, see the Glossary at support.dell.com/manuals.

System Messages

System messages appear on the screen to notify you of a possible problem with the system.

NOTE: If you receive a system message not listed in the table, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

Table 1-2. System Messages

Message

Causes

Corrective Actions

 

 

 

Alert! iDRAC6 not

The iDRAC6 is not

Wait for the system to

responding.

responding to BIOS

reboot.

Rebooting.

communication either

 

 

because it is not functioning

 

 

properly or has not

 

 

completed initialization. The

 

 

system will reboot.

 

About Your System

41

Page 41
Image 41