57-42

Software Configuration Guide—Release 15.0(2)SG
OL-23818-01
Chapter 57 Configuring Ethernet OAM and CFM
Enabling and Configuring Ethernet OAM
GigabitEthernet1/1
General
-------
Admin state: enabled
Mode: active
PDU max rate: 10 packets per second
PDU min rate: 1 packet per 1 second
Link timeout: 5 seconds
High threshold action: error disable interface
Link fault action: no action
Dying gasp action: no action
Critical event action: no action
Link Monitoring
---------------
Status: supported (on)
Symbol Period Error
Window: 100 x 1048576 symbols
Low threshold: 5 error symbol(s)
High threshold: 5000 error symbol(s)
Frame Error
Window: 10 x 100 milliseconds
Low threshold: 8 error frame(s)
High threshold: 8000 error frame(s)
Frame Period Error
Window: 1000 x 10000 frames
Low threshold: 9 error frame(s)
High threshold: 9000 error frame(s)
Frame Seconds Error
Window: 100 x 100 milliseconds
Low threshold: 1 error second(s)
High threshold: none
Receive-Frame CRC Error
Window: 10 x 100 milliseconds
Low threshold: 10 error frame(s)
High threshold: 1000 error frame(s)
Transmit-Frame CRC Error: Not Supported
Configuring Ethernet OAM Remote Failure Indications

You can configure an error-disable action to occur on an interface when the following occur:

Crossing the high thresholds configured on the interface for link monitoring

On reception of Dying Gasp, executing shut on the interface

On reception of Dying Gasp, executing reload command

On reception of Dying Gasp, executing no ethernet oam command on the interface