62-14
Software Configuration Guide—Release 15.0(2)SG
OL-23818-01
Chapter 62 Performing Diagnostics
Packet memory errors: 0 0
Current alert level: green
Per 5 seconds in the last minute:
0 0 0 0 0 0 0 0 0 0
0 0
Per minute in the last hour:
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
Per hour in the last day:
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0
Per day in the last 30 days:
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
Direct memory test failures per minute in the last hour:
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0
Potential false positives: 0 0
Ignored because of rx errors: 0 0
Ignored because of cdm fifo overrun: 0 0
Ignored because of oir: 0 0
Ignored because isl frames received: 0 0
Ignored during boot: 0 0
Ignored after writing hw stats: 0 0
Ignored on high gigaport: 0
Ongoing diag action mode: Normal
Last 1000 Memory Test Failures:
Last 1000 Packet Memory errors:
First 1000 Packet Memory errors:
___________________________________________________________________________
Switch#
The following example shows the output for a WS-X45-SUP6-E supervisor engine:
Switch# show diagnostic result module 3 detail
module 3: SerialNo : XXXXXXXXXXX
Overall diagnostic result: PASS
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
1) supervisor-bootup --------------->
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 1
Last test execution time ----> Oct 01 2007 17:37:04
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Oct 01 2007 17:37:04