Chapter 10 Environmental Monitoring and Power Management About Environmental Monitoring
When the system issues a major alarm, it starts a timer whose duration depends on the alarm. If the alarm
is not canceled before the timer expires, the system takes emergency action to protect itself from the
effects of overheating. The timer values and the emergency actions depend on the type of supervisor
engine.
Note Refer to the Catalyst 4500 Series Switch Module Installation Guide for information on LEDs, including
the startup behavior of the supervisor engine system LED.
Table 10-4 describes the alarms on Supervisor Engines II-Plus to V-10GE.
Table 10-5 describes the alarms on Supervisor Engine 6-E and Supervisor 6L-E.
Table 10-4 Alarms on Supervisor Engines II-Plus to V-10GE
Event Alarm
Type Supervisor LED
Color Timeout Description and Action
Chassis temperature exceeds the
critical threshold. Major Red 5 min Syslog message displays when the alarm is
issued.
Line cards are put in reset when the timeout
expires.
Supervisor fails power on
self-test (POST). Major Red Syslog message is displayed.
The supervisor engine fails to come up.
Chassis fan tray fails. Major Red 4 min Syslog message displays when the alarm is
issued.
Line cards are put in reset when the timeout
expires.
Chassis temperature exceeds the
warning threshold. Minor Orange Syslog message displays when the alarm is
issued.
Chassis fan tray experiences
partial failure. Minor Orange Syslog message displays when the alarm is
issued.
Table 10-5 Alarms on Supervisor Engine 6-E and Supervisor Engine 6L-E
Event Alarm
Type Supervisor LED
Color Timeout Description and Action
Card temperature exceeds the
critical threshold. Major Red 15 min Syslog message displays when the alarm is
issued.
See Table 10-2 for the action on timeout.
Card temperature exceeds the
shutdown threshold. Major Red 30 sec Syslog message displays when the alarm is
issued.
See Table 10-2 for the action on timeout.
Supervisor engine fails power-on
self-test (POST). Major Red Syslog message displays.
Supervisor engine fails to come up.