59-19
Software Configuration Guide—Release 15.0(2)SG
OL-23818-01
Chapter 59 Configuring Call Home Alert Group Trigger Events and Commands
Table 59-3 Call Home Alert Groups, Events, and Actions
Alert Group Call Home
Trigger Event Syslog Event Severity Description and CLI Commands Executed
Syslog Event logged to syslog. (Only sent to TAC if syslog
level 0, 1, or 2)
CLI commands executed:
show logging
show inventory
SYSLOG LOG_EMERG 7 System is unusable.
SYSLOG LOG_ALERT 6 Action must be taken immediately.
SYSLOG LOG_CRIT 5 Critical conditions.
SYSLOG LOG_ERR 4 Error conditions.
SYSLOG LOG_WARNING 3 Warning conditions.
SYSLOG LOG_NOTICE 2 Normal but signification condition.
SYSLOG LOG_INFO 1 Informational.
SYSLOG LOG_DEBUG 0 Debug-level messages.
Environmental Events related to power, fan, and environment sensing
elements, such as temperature alarms. (Sent to TAC.)
CLI commands executed:
show module
show environment
show logging
show power
show inventory
TEMP_FAILU
RE TempHigh 5 The temperature of the chassis is above the normal
threshold.
TEMP_FAILU
RE Critical Temp 5 The temperature of the chassis has risen above the
critical threshold.
TEMP_FAILU
RE Shutdown Temp 5 The temperature of the chassis is very high and the
system will be shut down.
TEMP_FAILU
RE Some Temp Sensors
Failed 3 Some of the temperature sensors have failed.
TEMP_FAILU
RE All Temp Sensors
Failed 5 All temperature sensors have failed.
TEMP_RECO
VER TempOk 5 The temperature of the chassis is normal.
POWER_FAIL
URE PowerSupplyBad 5 A power supply has failed or has been turned off.
POWER_REC
OVERY PowerSupplyGood 5 A failed power supply has been fixed.
POWER_FAIL
URE PowerSupplyFanBad 3 A power supply fan has failed.