57-37
Software Configuration Guide—Release 15.0(2)SG
OL-23818-01
Chapter 57 Configuring Ethernet OAM and CFM Enabling and Configuring Ethernet OAM
Link fault action: no action
Dying gasp action: no action
Critical event action: no action
Link Monitoring
---------------
Status: supported (on)
Symbol Period Error
Window: 100 x 1048576 symbols
Low threshold: 1 error symbol(s)
High threshold: none
Frame Error
Window: 10 x 100 milliseconds
Low threshold: 1 error frame(s)
High threshold: none
Frame Period Error
Window: 1000 x 10000 frames
Low threshold: 1 error frame(s)
High threshold: none
Frame Seconds Error
Window: 100 x 100 milliseconds
Low threshold: 1 error second(s)
High threshold: none
Receive-Frame CRC Error
Window: 10 x 100 milliseconds
Low threshold: 10 error frame(s)
High threshold: none
Transmit-Frame CRC Error: Not Supported
Enabling Ethernet OAM Remote Loopback
You must enable Ethernet OAM remote loopback on an interface for the local OAM client to initiate
OAM remote loopback operations. Changing this setting causes the local OAM client to exchange
configuration information with its remote peer. Remote loopback is disabled by default.
Remote loopback has these limitations:
Only data packets are looped back.
You cannot configure Ethernet OAM remote loopback on ISL ports or ports that belong to an
EtherChannel.
Remote loopback can be supported on a max of 16 ports.
To enable Ethernet OAM remote loopback on an interface, follow these steps:
Command Purpose
Step 1 Switch# configure terminal Enters global configuration mode.
Step 2 Switch(config)# interface interface-id Defines an interface to configure as an EOM interface, and
enters interface configuration mode.