62-5
Software Configuration Guide—Release 15.0(2)SG
OL-23818-01
Chapter 62 Performing Diagnostics
received by the cpu, the port passes the test. Sometimes one port
or a group of ports sharing common components fail. The linecard
is then placed in partial faulty mode. If no ports can loop back
traffic, the board is placed in faulty state.
Switch#
This example shows how to display the online diagnostic results for module 6:
Switch# show diagnostic result module 6
Current bootup diagnostic level: minimal
module 6: SerialNo : JAB0815059L
Overall Diagnostic Result for module 6 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) linecard-online-diag ------------> .
2) online-diag-tdr:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U . U U U U U U U U U U U U U U U U U U U U U
3) stub-rx-errors ------------------> .
4) supervisor-rx-errors ------------> .
Switch#
This example shows how to display the online diagnostic results details for module 6:
Switch# show diagnostic result module 6 detail
Current bootup diagnostic level: minimal
module 6: SerialNo : JAB0815059L
Overall Diagnostic Result for module 6 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
1) linecard-online-diag ------------> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 1
Last test testing type ------> n/a
Last test execution time ----> Jun 01 2009 11:19:36
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Jun 01 2009 11:19:36
Total failure count ---------> 0
Consecutive failure count ---> 0
Slot Ports Card Type Diag Status Diag Details
---- ----- -------------------------------------- ---------------- ------------
6 24 10/100/1000BaseT (RJ45)V, Cisco/IEEE Passed None