E-7

Power-On Self Test Message

Continued

 

Message

Beeps*

Probable Cause

Recommended Action

1151-System Board

2S

Both external and internal serial

Run Computer Setup or

Com Port 1 Address

 

ports are assigned to COM1.

Windows NT utilities.

Assignment Conflict

 

 

 

 

 

 

 

1152-System Board

2S

Both external and internal serial

Run Computer Setup or

Com Port 2 Address

 

ports are assigned to COM2.

Windows NT utilities.

Assignment Conflict

 

 

 

 

 

 

 

1720-SMART Hard

None

Hard drive is about to fail.

Back up contents and

Drive detects imminent

 

 

replace hard drive.

failure

 

 

 

 

 

 

 

1771-Primary Disk

2S

Internal and external hard drive

Run Computer Setup or

Port Address

 

controllers are both assigned to

Windows NT utilities.

Assignment Conflict

 

the primary address.

 

 

 

 

 

1772-Secondary Disk

2S

Internal and external hard drive

Run Computer Setup or

Port Address

 

controllers are both assigned to

Windows NT utilities.

Assignment Conflict

 

the secondary address.

 

 

 

 

 

1780-Disk 0 Failure

None

Hard drive/format error

Run Compaq Diagnostics

 

 

 

for Windows NT. See

 

 

 

Chapter 2, “Software.”

 

 

 

 

1781-Disk 1 Failure

None

Hard drive/format error

Run Compaq Diagnostics

 

 

 

for Windows NT. See

 

 

 

Chapter 2, “Software.”

 

 

 

 

* L = Long, S = Short

Continued

Compaq Professional Workstation AP200 Reference Guide