Imaging Commands

Image Ship - IMGSHP

An image is taken whenever the trigger of the unit is pressed, or when the Image Snap (IMGSNP) command is processed. The last image is always stored in memory. You may “ship” the image by using the IMG- SHP command.

The image ship command has many different modifiers that can be used to change the look of the image output by the scanner. Modifiers affect the image that is transmitted, but do not affect the image in memory.

Modifiers always begin with numbers and end with a letter (case insensi- tive). Any number of modifiers may be appended to the IMGSHP com- mand. For example, you can use the following command to ship a bitmap image with gamma correction and document image filtering:

IMGSHP8F75K26U

IMGSHP Modifiers

A - Infinity Filter: Enhances pictures taken from very long distances (greater than 10 feet or 3 m).

0A Infinity filter off (default)

1A Infinity filter on

C - Compensation: Flattens the image to account for variations in illu- mination across the image.

0C Compensation disabled (default)

1C Compensation enabled

D - Pixel Depth: Indicates the number of bits per pixel in the transmit- ted image (KIM or BMP format only).

8D 8 bits per pixel, grayscale image (default)

1D 1 bit per pixel, black and white image

7-4

PowerScan® 7000 2D

Page 122
Image 122
Datalogic Scanning 7000 manual Image Ship Imgshp, Imgshp Modifiers