Output

Presentation LED Timer

When an imager is in presentation mode, the LEDs turn off immediately after a bar code is decoded. The imager can be programmed to continue scanning and to keep the LEDs on for a short time after by scanning the LEDs On bar code below. Default = LEDs On.

* LEDs On

LEDs Off

Presentation Sensitivity

Presentation Sensitivity is a numeric range that increases or decreases the imager's reaction time to bar code presentation. To set the sensitivity, scan the Sensitivity bar code, then scan the degree of sensitivity (from 0-

20)from the Programming Chart on page B-5, and Save. 0 is the most

sensitive setting, and 20 is the least sensitive. Default = 1.

Sensitivity

Hands Free Time-Out

The Scan Stand and Presentation Modes are referred to as “hands free” modes. If the imager’s trigger is pulled when using a hands free mode, the imager changes to manual trigger mode. You can set the time the imager should remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls) the imager reverts to the original hands free mode.

3-8

PowerScan® 7000 2D

Page 38
Image 38
Datalogic Scanning 7000 manual Hands Free Time-Out, Presentation LED Timer, Presentation Sensitivity, LEDs On LEDs Off