Output Sequence Overview

5.End Output Sequence Editor

Scan F F to enter an Output Sequence for an additional symbol- ogy, or Save to save your entries.

Other Programming Selections

Discard

This exits without saving any Output Sequence changes.

Output Sequence Examples

In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the imager to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.

Code 93 must be enabled to use this example.

NOTE

A - Code 39

B - Code 128

C - Code 93

You would set up the sequence editor with the following command line:

SEQBLK62999941FF6A999942FF69999943FF

Product Reference Guide

3-19

Page 49
Image 49
Datalogic Scanning 7000 manual Output Sequence Examples, Other Programming Selections, Discard