Output

Output Sequence Editor

This programming selection allows you to program the Imager to output data (when scanning more than one symbol) in whatever order your application requires, regardless of the order in which the bar codes are scanned. Reading the Default Sequence symbol programs the Imager to the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol.

 

To make Output Sequence Editor selections,

 

you’ll need to know the code I.D., code length,

 

and character match(es) your application

 

requires. Use the Alphanumeric symbols from

NOTE

the Programming Chart on page B-5 to read

 

these options.

To Add an Output Sequence

1.Scan the Enter Sequence symbol (see Multiple Symbols on page 3- 22).

2.Code I.D.

On the Symbology Chart on page A-1, find the symbology to which you want to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart on page B-5.

3.Length

Specify what length (up to 9999 characters) of data output will be acceptable for this symbology. Scan the four digit data length from the Programming Chart. (Note: 50 characters is entered as 0050.

9999 is a universal number, indicating all lengths.) When calculat- ing the length, you must count any programmed prefixes, suffixes, or formatted characters as part of the length (unless using 9999).

4.Character Match Sequences

From the ASCII Conversion Chart (Code Page 1252) on page A-4, find the Hex value that represents the character(s) you want to match. Use the Programming Chart to read the alphanumeric combination that represents the ASCII characters. (99 is the Uni- versal number, indicating all characters.)