Error Code | Message Information |
|
|
|
| 5. | If the issue persists, see Getting Help. |
FAN0000 | Message | Fan <number> RPM is less than the lower warning threshold. | |
| |||
| Details | Fan operating speed is out of range. | |
| Action | Remove and reinstall the fan. If the issue persists, see Getting Help. | |
FAN0001 | Message | Fan <number> RPM is less than the lower critical threshold. | |
| |||
| LCD Message | Fan <number> RPM is outside of range. Check fan. | |
| Details | Fan operating speed is out of range. | |
| Action | Remove and reinstall the fan. If the issue persists, see Getting Help. | |
FAN1201 | Message | Fan redundancy is lost. | |
| |||
| LCD Message | Fan redundancy is lost. Check fans. | |
| Details | Fan has failed. | |
| Action | Remove and reinstall failed fans or install additional fans. | |
HWC1001 | Message | The <name> is absent. | |
| |||
| LCD Message | The <name> is absent. Check hardware. | |
| Details | The absent device may be necessary for proper operation. System | |
|
| functionality may be degraded. | |
| Action | Reinstall or reconnect the hardware. | |
HWC2003 | Message | The storage <name> cable is not connected, or is improperly | |
| |||
|
| connected. | |
| LCD Message | Storage <name> cable or interconnect failure. Check connection. | |
| Details | The cable may be necessary for proper operation. System | |
|
| functionality may be degraded. | |
| Action | Check if the cable is present, then reinstall or reconnect. | |
HWC2005 | Message | The system board <name> cable is not connected, or is improperly | |
| |||
|
| connected. | |
| LCD Message | System board <name> cable connection failure. Check connection. | |
| Details | The cable may be necessary for proper operation. System | |
|
| functionality may be degraded. |
144