Error Code | Message Information |
|
| Action | |
|
| issues persists, contact support. |
TMP0118 | Message | The system inlet temperature is less than the lower warning |
| ||
|
| threshold. |
| LCD Message | System inlet temperature is outside of range. |
| Details | Ambient air temperature is too cool. |
| Action | Check the system operating environment. |
TMP0119 | Message | The system inlet temperature is less than the lower critical threshold. |
| ||
| LCD Message | System inlet temperature is outside of range. |
| Details | Ambient air temperature is too cool. |
| Action | Check the system operating environment. |
TMP0120 | Message | The system inlet temperature is greater than the upper warning |
| ||
|
| threshold. |
| LCD Message | System inlet temperature is outside of range. |
| Details | Ambient air temperature is too warm or one or more fans may have |
|
| failed. |
| Action | Check the system operating environment and review event log for fan |
|
| failures. |
TMP0121 | Message | The system inlet temperature is greater than the upper critical |
| ||
|
| threshold. |
| LCD Message | System inlet <name> temperature is outside of range. Check Fans. |
| Details | Ambient air temperature is too warm or one or more fans may have |
|
| failed. |
| Action | Check the system operating environment and review event log for fan |
|
| failures. |
VLT0204 | Message | The system board <name> voltage is outside of the allowable range. |
| ||
| LCD Message | System board voltage is outside of range. |
| Details | System hardware detected an over voltage or under voltage |
|
| condition. |
If multiple voltage exceptions occur consecutively the system may power down in
154