Error Code | Message Information |
|
| LCD Message | Memory mirror lost on <location>. Power cycle system. |
| Details | The memory may not be seated correctly, misconfigured, or has |
|
| failed. |
| Action | Check the memory configuration. |
|
| issue persists, see Getting Help. |
MEM1208 | Message | Memory spare redundancy is lost. Check memory device at location |
| ||
|
| <location>. |
| LCD Message | Memory spare lost on <location>. Power cycle system. |
| Details | Memory sparing is no longer available. |
| Action | |
MEM8000 | Message | Correctable memory error logging disabled for a memory device at |
| ||
|
| location <location>. |
| LCD Message | SBE log disabled on <location>. |
| Details | Errors are being corrected but no longer logged. |
| Action | Review system logs for memory exceptions. Reinstall memory at |
|
| location <location>. |
PCI1302 | Message | A bus |
| ||
|
| device<device> function <func>. |
| Details | System performance may be degraded. The device has failed to |
|
| respond to a transaction. |
| Action | Cycle input power, update component drivers, if device is removable, |
|
| reinstall the device. |
PCI1304 | Message | An I/O channel check error was detected. |
| ||
| LCD Message | I/O channel check error detected. Power cycle system. |
| Action | Cycle input power, update component drivers, if device is removable, |
|
| reinstall the device. |
PCI1308 | Message | A PCI parity error was detected on a component at bus |
| ||
|
| <bus>device<device>function <func>. |
| LCD Message | PCI parity error on bus <bus> device <device> function <func>. |
|
| Power cycle system. |
| Details | System performance may be degraded, PCI device may fail to |
|
| operate, or system may fail to operate. |
146