Error Code

Message Information

 

 

LCD Message

Memory mirror lost on <location>. Power cycle system.

 

Details

The memory may not be seated correctly, misconfigured, or has

 

 

failed.

 

Action

Check the memory configuration. Re-seat the memory modules. If the

 

 

issue persists, see Getting Help.

MEM1208

Message

Memory spare redundancy is lost. Check memory device at location

 

 

 

<location>.

 

LCD Message

Memory spare lost on <location>. Power cycle system.

 

Details

Memory sparing is no longer available.

 

Action

Re-seat the memory modules. If the issue persists, see Getting Help.

MEM8000

Message

Correctable memory error logging disabled for a memory device at

 

 

 

location <location>.

 

LCD Message

SBE log disabled on <location>. Re-seat memory.

 

Details

Errors are being corrected but no longer logged.

 

Action

Review system logs for memory exceptions. Reinstall memory at

 

 

location <location>.

PCI1302

Message

A bus time-out was detected on a component at bus <bus>

 

 

 

device<device> function <func>.

 

Details

System performance may be degraded. The device has failed to

 

 

respond to a transaction.

 

Action

Cycle input power, update component drivers, if device is removable,

 

 

reinstall the device.

PCI1304

Message

An I/O channel check error was detected.

 

 

LCD Message

I/O channel check error detected. Power cycle system.

 

Action

Cycle input power, update component drivers, if device is removable,

 

 

reinstall the device.

PCI1308

Message

A PCI parity error was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

LCD Message

PCI parity error on bus <bus> device <device> function <func>.

 

 

Power cycle system.

 

Details

System performance may be degraded, PCI device may fail to

 

 

operate, or system may fail to operate.

146

Page 146
Image 146
Dell E23S Series owner manual MEM1208 Message, MEM8000 Message, PCI1302 Message, PCI1304 Message, PCI1308 Message