Error Code | Message Information |
|
| Action | Check if the cable is present, then reinstall or reconnect. |
MEM0000 | Message | Persistent correctable memory errors detected on a memory device |
| ||
|
| at location(s) <location>. |
| Details | This is an early indicator of a possible future uncorrectable error. |
| Action | |
MEM0001 | Message | |
| ||
|
| <location>. |
| LCD Message | |
| Details | The memory module has encountered an uncorrectable error. System |
|
| performance may be degraded. The operating system and/or |
|
| applications may fail as a result. |
| Action | |
MEM0007 | Message | Unsupported memory configuration; check memory device at location |
| ||
|
| <location>. |
| LCD Message | Unsupported memory configuration. Check memory <location>. |
| Details | The memory may not be seated correctly, misconfigured, or has |
|
| failed. Memory size is reduced. |
| Action | Check the memory configuration. |
|
| issue persists, see Getting Help. |
MEM0701 | Message | Correctable memory error rate exceeded for <location>. |
| ||
| Details | The memory may not be operational. This an early indicator of a |
|
| possible future uncorrectable error. |
| Action | |
MEM0702 | Message | Correctable memory error rate exceeded for <location>. |
| ||
| LCD Message | Correctable memory error rate exceeded for <location>. |
|
| memory. |
| Details | The memory may not be operational. This an early indicator of a |
|
| possible future uncorrectable error. |
| Action | |
MEM1205 | Message | Memory mirror redundancy is lost. Check memory device at |
|
location(s) <location>.
145