Dell HR675 E171F Pcie Fatal, Err B## D##, Err Slot #, E1810 HDD ## Fault, E1811 HDD ## Rbld, Abrt

Models: HR675

1 194
Download 194 pages 21.08 Kb
Page 25
Image 25

Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E171F

PCIE Fatal

The system BIOS has

Remove and reseat the

 

Err B## D##

reported a PCIe fatal error

PCIe expansion cards. If

 

F##

on a component that resides

the problem persists, see

 

 

in PCIe configuration space

"Troubleshooting

 

 

at bus ##, device ##,

Expansion Cards" on

 

 

function ##.

page 159. If

 

PCIE Fatal

The system BIOS has

troubleshooting does not

 

resolve the problem, see

 

Err Slot #

reported a PCIe fatal error

 

"Getting Help" on

 

 

on a component that resides

 

 

in the specified slot.

page 175.

 

 

 

 

 

 

 

E1810

HDD ## Fault

The SAS subsystem has

See "Troubleshooting a

 

 

determined that hard drive

Hard Drive" on page 153.

 

 

## has experienced a fault.

 

 

 

 

 

E1811

HDD ## Rbld

Specified hard drive has

See "Troubleshooting a

 

Abrt

ended rebuild before

Hard Drive" on page 153.

 

 

completion.

 

 

 

 

 

E1812

HDD ##

The specified hard drive has

Information only.

 

Removed

been removed from the

 

 

 

system.

 

E1913 CPU &

The BMC firmware does not

Firmware

support the CPU.

Mismatch

 

Update to the latest BMC firmware. See the BMC User’s Guide for more information on setup and use of BMC.

E1A14 SAS Cable A SAS cable A is missing or bad.

Reseat the cable. If the problem persists, replace the cable.

E1A15 SAS Cable B SAS cable B is missing or bad.

Reseat the cable. If the problem persists, replace the cable.

E1A15 SAS Cable C SAS cable C is missing or bad.

Reseat the cable. If the problem persists, replace the cable.

About Your System

25

Page 25
Image 25
Dell HR675 E171F Pcie Fatal, Err B## D##, Err Slot #, E1810 HDD ## Fault, E1811 HDD ## Rbld, Abrt, E1812 HDD ##, Removed