Table 1-6. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

SATA PORT n drive

SATA port x was turned

See "Troubleshooting a Hard

not found

on in setup, but a drive

Drive" on page 153 for the

 

was not found.

appropriate drive(s) installed

 

 

in your system.

 

 

 

Sector not found

Faulty hard drive, USB

See "Troubleshooting a USB

Seek error

device, or USB medium.

Device" on page 138 or

 

"Troubleshooting a Hard

Seek operation

 

 

Drive" on page 153 for the

failed

 

 

appropriate drive(s) installed

 

 

 

 

in your system.

 

 

 

Shutdown failure

Shutdown test failure.

See "Troubleshooting System

 

 

Memory" on page 146.

The amount of

Memory has been added

system memory has

or removed or a memory

changed

module may be faulty.

If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module (see "Troubleshooting System Memory" on page 146).

Time-of-day clock

Faulty battery or faulty

See "Troubleshooting the

stopped

chip.

System Battery" on page 143.

 

 

 

Time-of-day not set

Incorrect time or date

Check the time and date

- please run SETUP

settings; faulty system

settings (see "Using the

program

battery.

System Setup Program" on

 

 

page 41). If the problem

 

 

persists, replace the system

 

 

battery (see "System Battery"

 

 

on page 118).

 

 

 

Timer chip counter

Faulty system board.

See "Getting Help" on

2 failed

 

page 175.

36

About Your System

Page 36
Image 36
Dell HR675 Sata Port n drive, Not found, Sector not found, Seek error, Seek operation, Shutdown failure, Amount, Changed