Mediant 2000 SIP

Table L-2: acBoardConfigurationError Alarm Trap

Corrective Action:

Inspect the run-time specific string to determine the nature of the configuration error. Fix the configuration error using the appropriate tool: Web interface, EMS, or ini file. Save the configuration and if necessary reset the device.

 

Table L-3: acBoardTemperatureAlarm Alarm Trap

 

 

 

Alarm:

 

acBoardTemperatureAlarm

OID:

 

1.3.6.1.4.1.5003.9.10.1.21.2.0.3

Default Severity

 

Critical

Event Type:

 

equipmentAlarm

Probable Cause:

 

temperatureUnacceptable (50)

Alarm Text:

 

Board temperature too high

Status Changes:

 

 

Condition:

 

Temperature is above 60 degrees C (140 degrees F)

Alarm status:

 

Critical

 

 

 

Condition:

 

After raise, temperature falls below 55 degrees C (131 degrees F)

Alarm status:

 

Cleared

Corrective Action:

 

Inspect the system. Determine if all fans in the system are properly operating.

 

Table L-4: acBoardEvResettingBoard Alarm Trap

 

 

 

Alarm:

 

acBoardEvResettingBoard

OID:

 

1.3.6.1.4.1.5003.9.10.1.21.2.0.5

Default Severity

 

Critical

Event Type:

 

equipmentAlarm

Probable Cause:

 

outOfService (71)

Alarm Text:

 

User resetting board

Status Changes:

 

 

Condition:

 

When a soft reset is triggered via the Web interface or SNMP.

Alarm status:

 

Critical

 

 

 

Condition:

 

After raise

Alarm status:

 

Status stays critical until reboot. A clear trap is not sent.

Corrective Action:

 

A network administrator has taken action to reset the device. No corrective action is

 

 

required.

 

Table L-5: acFeatureKeyError Alarm Trap

 

 

 

 

 

Alarm:

acFeatureKeyError

 

 

OID:

1.3.6.1.4.1.5003.9.10.1.21.2.0.6

 

Default Severity

Critical

 

 

Event Type:

processingErrorAlarm

 

 

Probable Cause:

configurationOrCustomizationError (7)

 

Alarm Text:

Feature key error

 

 

Status Changes:

 

 

 

Note:

Support of this alarm is pending

 

Condition:

A feature key error has been detected

 

Alarm status:

Critical

 

 

 

 

 

 

 

 

 

 

Mediant 2000 SIP User’s Manual

272

Document #: LTRT-72504

Page 272
Image 272
Nortel Networks TP-1610 SIP Table L-3 acBoardTemperatureAlarm Alarm Trap, Table L-4 acBoardEvResettingBoard Alarm Trap