Mediant 2000 SIP

Note: The information in columns ‘Quality Status’ and ‘Quality Info.’ (per IP address) is reset if two minutes elapse without a call to that destination.

To view the IP connectivity information, take these 2 steps:

1.Set ‘AltRoutingTel2IPEnable’ to 1 or 2.

2.Open the ‘IP Connectivity’ screen (Status & Diagnostics menu > Gateway Statistics submenu > IP Connectivity); the ‘IP Connectivity’ screen is displayed (Figure 5-22).

Figure 5-22: IP Connectivity Screen

 

 

Table 5-8: IP Connectivity Parameters

 

 

 

 

 

Column Name

Description

 

 

 

 

IP Address

IP address defined in the destination IP address field in the Tel to IP Routing table.

 

or

 

 

 

 

IP address that is resolved from the host name defined in the destination IP address field in the

 

Tel to IP Routing table.

 

Host Name

Host name (or IP address) defined in the destination IP address field in the Tel to IP Routing

 

table.

 

 

Connectivity Method

The method according to which the destination IP address is queried periodically (currently

 

only by ping).

 

 

Connectivity Status

Displays the status of the IP address’ connectivity according to the method in the ‘Connectivity

 

Method’ field.

 

 

 

Can be one of the following:

 

 

OK

= Remote side responds to periodic connectivity queries.

 

Lost

= Remote side didn’t respond for a short period.

 

 

Fail

= Remote side doesn’t respond.

 

 

Init

= Connectivity queries not started (e.g., IP address not resolved).

 

Disable

= The connectivity option is disabled (‘AltRoutingTel2IPMode’ equals 0 or 2).

Quality Status

Determines the QoS (according to packet loss and delay) of the IP address.

 

Can be one of the following:

 

 

Unknown

= Recent quality information isn’t available.

 

 

OK

 

 

 

Poor

 

 

 

Note 1: This field is applicable only if the parameter ‘AltRoutingTel2IPMode’ is set to 2 or 3.

 

Note 2: This field is reset if no QoS information is received for 2 minutes.

 

 

 

 

 