Mediant 2000 SIP

Figure 3-1: 19-inch Rack & Desktop Accessories

3.3Mounting the Mediant 2000

The Mediant 2000 can be mounted on a desktop, or installed in a standard 19-inch rack. Refer to Section 3.4 on page 30 for cabling the Mediant 2000.

3.3.1Mounting the Mediant 2000 on a Desktop

No brackets are required. Optionally, attach the four (supplied) anti-slide bumpers to the base of the Mediant 2000 and place it on the desktop in the position you require.

3.3.2Installing the Mediant 2000 in a 19-inch Rack

Users can install the device in a standard 19-inch rack either by placing the device on a shelf preinstalled in the rack (preferred method), or by attaching the device directly to the rack’s frame via integral brackets.

Before rack mounting the chassis, attach the two (supplied) brackets to the front sides of the device (refer to Figure 3-2).

To attach the two front side brackets, take these 3 steps:

1.Remove the 2 screws nearest the front panel on either side of the device.

2.Align a bracket over 2 holes on one side (so that the bracket’s larger holes face front) and with the 2 supplied replacement screws, screw in the bracket.

3.Perform the same procedure on the other side.

Mediant 2000 SIP User’s Manual

28

Document #: LTRT-72504

Page 28
Image 28
Nortel Networks TP-1610 SIP Mounting the Mediant 2000 on a Desktop, Installing the Mediant 2000 in a 19-inch Rack