Mediant 2000 SIP User’s Manual

J. SS7 Tunneling

Table J-4: SS7 Signaling Link (continues on pages 236 to 237)

ini File Parameter Name

Description

 

 

 

 

SS7_LINK_GROUP_ID

Determines the group ID (M3UA) of signaling link.

 

 

The valid range is 0 to 0xFFFF. The default value is 0.

 

ATM_SAAL_LINK_PROFILE_NUM

Determines the ATM SAAL Link profile number

 

 

The valid range is 0 to (MAX_SAAL_PROFILES-1). The default value is 0.

 

ATM_SAAL_LINK_TYPE

Determines the ATM SAAL link Type PVC/SVC

 

 

The valid range is ATM_VCC_TYPE_PVC to ATM_VCC_TYPE_SVC. The

 

 

default value is ATM_VCC_TYPE_PVC.

 

ATM_SAAL_LINK_PORT_NUM

Determines the ATM SAAL link port num

 

 

The valid range is 0 to ATMDB_ATM_MAX_INTERFACES_RANGE. The

 

 

default value is 0.

 

ATM_SAAL_LINK_VPI

Determines the ATM SAAL link VPI

 

 

The valid range is 0 to 255. The default value is 0.

 

ATM_SAAL_LINK_VCI

Determines the ATM SAAL link VCI

 

 

The valid range is 0 to 0xFFFF. The default value is 0.

 

SS7_LINK_TNL_MGC_LINK_NUMBER

Determines the MTP2 Tunneling: MGC link number (MTP2 \other side\ of

 

 

signaling link.

 

 

The valid range is 0 to 7. The default value is 0.

 

SS7_LINK_TNL_ALIGNMENT_MODE

Determines the MTP2 Tunneling: Alignment mode of signaling links in

 

 

tunnel.

 

 

The valid range is 0 to 255. The default value is

 

 

M3B_ALIGNMENT_EMERGENCY.

 

SS7_LINK_TNL_CONGESTION_MODE

Determines the MTP2 Tunneling: Congestion mode of signaling links in

 

 

tunnel.

 

 

The valid range is 0 to 255. The default value is

 

 

M3B_CONGESTION_ACCEPT.

 

SS7_LINK_TNL_WAIT_START_COMP

Determines the MTP2 Tunneling Timer: wait start complete.

 

LETE_TIMER

The valid range is 500 to 0xFFFFFFFF. The default value is 30000.

 

SS7_LINK_TNL_OOS_START_DELAY

Determines the MTP2 Tunneling Timer: OOS start delay.

 

_TIMER

The valid range is 500 to 0xFFFFFFFF. The default value is 5000.

 

SS7_LINK_TNL_WAIT_OTHER_SIDE_I

Determines the MTP2 Tunneling Timer: wait other side inservice.

 

NSV_TIMER

The valid range is 500 to 0xFFFFFFFF. The default value is 30000.

 

SS7_LINKSET_SN_INDEX

Determines the first index field for line.

 

 

The valid range is 0 to 1. The default value is 0.

 

SS7_LINKSET_LINKSET_INDEX

Determines the second index field for line.

 

 

The valid range is 0 to 7. The default value is 0.

 

SS7_LINKSET_ROWSTATUS

Determines the RowStatusField for line.

 

 

The valid range is acPARAMSET_ROWSTATUS_DOESNOTEXIST to

 

 

acPARAMSET_ROWSTATUS_DESTROY. The default value is

 

 

acPARAMSET_ROWSTATUS_DOESNOTEXIST.

 

SS7_LINKSET_ACTION

Determines the management field for actions.

 

 

The valid range is acSS7LINKSET_PS_ACTION_NONE to

 

 

acSS7LINKSET_PS_ACTION_DEACTIVATE. The default value is

 

 

acSS7LINKSET_PS_ACTION_NONE.

 

SS7_SN_ACTION_RESULT

Determines the management field for actions result.

 

 

The valid range is acPARAMSET_ACTION_RESULT_SUCCEEDED to

 

 

acPARAMSET_ACTION_RESULT_FAILED. The default value is

 

 

acPARAMSET_ACTION_RESULT_SUCCEEDED.

 

J.5 SS7 MTP2 Tunneling ini File Example

For the SS7 MTP2 tunneling ini file example, note the following:

The first ini file acts as an MTP2 tunneling central side (M2UA MGC links).

Version 4.4

237

July 2005

Page 237
Image 237
Nortel Networks TP-1610 SIP user manual SS7 MTP2 Tunneling ini File Example, SS7LINKGROUPID